Discover Battery Algorithm Recommendations

  • Updated

Product Series: All

Article No: FAQ100

Safety Information

Caution_2.png

CAUTION: Use of charge algorithms with batteries that were not designed for them, is done at your own risk, Delta-Q is continuously testing and updating charge algorithms for various batteries. Though many algorithms will work with a range of batteries, variations in manufacturing, chemical composition, health, and other properties may cause unacceptable charging performance.

This document is only for the use of Authorized OEMs and Distributors. Use by any other parties may void the battery and/or charger warranty.

 

Always closely monitor a suggested battery/algorithm combination for at least three cycles to ensure the batteries are being properly charged. If you are not sure of how to monitor a battery charge, contact Delta-Q Technical Support for advice.

 

Download and Install algorithms yourself 

To download and add the common algorithms listed in the "Charge Profile List" and "Application Chart",  see the articles below.

Download Algorithms for IC Series Battery Chargers

Download Algorithms for QuiQ Series Battery Chargers

For support of lithium batteries: 

Choosing an Algorithm for a Lithium Battery

 

Algorithm recommendation

Model Type Voltage Capacity @ 20Hr Rate Algorithm
EV506G-170 GEL 6 170/C5 51
EV506G-180 GEL 6 180/C5 51
EV512G-103 GEL 12 103/C5 52
EV627A-A AGM 6 210 43
EVGC6A-A AGM 6 220 43
EVGT6A-A AGM 6 260 43
EV506A-230 AGM 6 230 43
EV305A-A AGM 6 330 43
EVL16A-A AGM 6 390 43
EVGC8A-A AGM 8 160 42
EVGT8A-A AGM 8 200 43
EV805A-A AGM 8 235 43
EV24A-A AGM 12 85 42
EV27A-A AGM 12 100 42
EV31A-A AGM 12 120 42
EV12A-A AGM 12 145 42
EV185A-A AGM 12 230 43
EV4DA-A AGM 12 235 43
EV8DA-A AGM 12 280 43
Share in