Trojan Battery Algorithm Recommendations

  • Updated

Product Series: All

Article No: FAQ153

Safety Information

Caution_2.png

CAUTION: Use of charge algorithms with batteries that were not designed for them, is done at your own risk, Delta-Q is continuously testing and updating charge algorithms for various batteries. Though many algorithms will work with a range of batteries, variations in manufacturing, chemical composition, health, and other properties may cause unacceptable charging performance.

This document is only for the use of Authorized OEMs and Distributors. Use by any other parties may void the battery and/or charger warranty.

 

Always closely monitor a suggested battery/algorithm combination for at least three cycles to ensure the batteries are being properly charged. If you are not sure of how to monitor a battery charge, contact Delta-Q Technical Support for advice.

 

Download and Install algorithms yourself 

To download and add the common algorithms listed in the "Charge Profile List" and "Application Chart",  see the articles below.

Download Algorithms for IC Series Battery Chargers

Download Algorithms for QuiQ Series Battery Chargers

For support of lithium batteries: 

Choosing an Algorithm for a Lithium Battery

 

Algorithm recommendation

 Trojan Model Battery Type Capacity at 20hr Rate Algorithms
Temp Compensated  Non-Temp Compensated 
24-AGM AGM 76 42 -
27-AGM AGM 89 42 -
31-AGM AGM 100 42 -
5SHP-AGM AGM 166 125 -
60AH-12V AGM 74 42 -
6V-AGM AGM 200 43 -
8D-AGM AGM 230 43 -
J305-AGM AGM 310 43 -
TE35-AGM AGM 243 43 -
24TMX Flooded 85 5 62
27TMH Flooded 115 5 62
27TMX Flooded 105 5 62
30XHS Flooded 130 5 62
31XHS Flooded 130 5 62
DC-8V Flooded 160 1 3
J150 Flooded 150 1 3
J150 Plus Flooded 150 1 3
J185E-AC Flooded 175 1 3
J185G-AC Flooded 185 1 3
J185H-AC Flooded 225 1 3
J185HG-AC Flooded 225 1 3
J185P-AC Flooded 205 1 3
J185PG-AC Flooded 205 1 3
J250G Flooded 235 1 3
J250P Flooded 250 1 3
J305G-AC Flooded 315 - 7
J305H-AC Flooded 360 - 7
J305HG-AC Flooded 360 - 7
J305P-AC Flooded 330 - 7
J305PG-AC Flooded 330 - 7
L16E-AC Flooded 370 - 7
L16G-AC Flooded 390 - 7
L16H Flooded 435 - 7
L16H-AC Flooded 435 - 7
L16HG-AC Flooded 435 - 7
L16P Flooded 420 - 7
L16P-AC Flooded 420 - 7
L16PG-AC Flooded 420 - 7
Ranger™ 160 Flooded 204 1 3
SCS150 Flooded 100 5 62
SCS200 Flooded 115 5 62
SCS225 Flooded 130 5 62
T-105 Flooded 225 1 3
T-105 Plus Flooded 225 1 3
T-125 Flooded 240 1 3
T-125 Plus Flooded 240 1 3
T-1260 Plus Flooded 140 5 62
T-1275 Flooded 150 1 3
T-1275 Plus Flooded 150 1 3
T-145 Flooded 260 - 7
T-145 Plus Flooded 260 - 7
T-875 Flooded 170 1 3
T-890 Flooded 190 1 3
TE35 Flooded 245 1 3
24-GEL Gel 85 6 -
27-GEL Gel 91 6 -
31-GEL Gel 102 6 -
6V-GEL Gel 189 26 -
8D-GEL Gel 225 26 -
TE35-GEL Gel 210 26 -

 

Share in