Faults and Error Codes of IC/RC/ICL/XV Series

  • Updated
Product Series: IC, RC, ICL, XV

Article No: FAQ121

This article lists fault (F_ _ _ ) and error (E_ _ _ ) codes on these chargers. Most of these will be reported over CAN and logged. Not all will be displayed on chargers with a user interface. If a unit is not functioning and nothing is indicated or logged, check and cycle both AC and DC. If this condition persists, replace the charger.

 

Please see the attached .pdf document version of the Delta-Q Fault and Error Codes List for IC/RC/ICL/XV Series chargers.

 

Fault Codes:

TypeCodeDescriptionTroubleshooting and/or Recommended Actions
FaultF001DC-DC Circuit Excessive LeakageInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF002PFC Circuit Excessive LeakageInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF003PFC Circuit Boost FailureInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF004Battery Current Sense Circuit FailureInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF005DC Relay Circuit - RationalityInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF006Battery Current Sense Circuit RationalityInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF007DC-DC Circuit FailureInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF008Not Used
FaultF009Internal Software ExceptionInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF010Fault on Connected ChargerStackable and VCIM systems:  Check connected chargers individually for faults.
FaultF016Internal Aux Relay Circuit FaultInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF017Control Pilot Voltage Range IssueCheck EVSE for proper operation. Check control pilot wire for damage.  Possible internal hardware fault.  If persists, replace the unit.
FaultF018Aux Output Fuse Circuit FailureInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF019Aux Output Voltage too HighCheck AUX DC connected to correct voltage battery (12V or 24V).   Possible internal hardware fault.  If persists, replace the unit.
FaultF020Internal Aux DCDC Short CircuitInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF021Internal Temperature Sensor FaultInternal charger fault. Remove AC and battery for minimum 30 MINUTES and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF022Internal Aux DCDC Circuit Failure Internal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF023PFC Circuit Performance Issue DetectedInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF024Internal Aux DCDC Failed to Turn OnInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.
FaultF025Internal Hardware Clock FaultInternal charger fault. Remove AC and battery for minimum 30 seconds and retry charger. If it fails again, do not continue to use the charger - replace the unit.

 

Error Codes:

TypeCodeDescriptionTroubleshooting and/or Recommended Actions
AlarmE001High Battery Voltage ErrorBattery Voltage is too high to start charge. Check the battery voltage and cable connections. Check battery size and condition. This error will automatically clear once the condition has been corrected.
AlarmE002Low Battery Voltage ErrorBattery Voltage is too low to start charge. Check the battery voltage and cable connections.  Check battery size and condition. This error will automatically clear once the condition has been corrected.
AlarmE003Charge TimeoutCharge Timeout caused by battery pack not reaching required voltage within safe time limit.
Possible causes: Charger output reduced due to high temperatures or low AC voltage. Poor battery health. Very deeply discharged battery. Poorly connected battery. Extra loads.  Battery too large for algorithm selected.
Possible solutions: Improve cooling air flow. Check for low AC voltage. Replace battery pack. Check DC connections. This error will automatically clear once the charger is reset by cycling DC.
AlarmE004Battery DefectiveBattery could not be trickle charged up to the minimum voltage. Check for shorted or damaged cells. Check battery pack voltage matches charger voltage.  Replace battery pack. Check DC connections. This error will automatically clear once the charger is reset by cycling DC.
AlarmE005Algorithm Specific AlarmContact Support for details if this alarm occurs.
AlarmE006Battery Temperature Sensor Short CircuitCheck temperature sensor wiring for short to ground then restart the charge.
AlarmE007Charge Amp-Hour Limit ExceededSafety limit exceeded. Possible causes: Poor battery health. Very deeply discharged battery. Poorly connected battery. High parasitic loads on battery while charging. Possible solutions: Replace battery pack. Check DC connections. Disconnect parasitic loads. This error will automatically clear once the charger is reset by cycling DC.
AlarmE008Battery Temperature Out of RangePossible battery temperature sensor error. Check temperature sensor and connections. Reset charger. This error will automatically clear once the condition has been corrected.
AlarmE009Battery Temperature Changing Too QuicklyCheck loose/corrosion on output cable or bad configuration if the battery temperature sensor is used for charge control.
AlarmE010Charger Output Short CircuitCharger DC terminals in contact with each other while charging. Check for short circuit in charging and battery cables.
AlarmE011Charger Disabled By External CommandCharger has been disabled by an external controller over the CANbus network. This error is logged in the data log and the charger sends out a CAN message.  It is not displayed.
AlarmE012Charger Output Reverse PolarityBattery is connected incorrectly. Check the battery connections. This error will automatically clear once the condition has been corrected.
AlarmE013Charger Output Current Not AcceptedBattery voltage is detected but the charger is unable to output current. This is normally caused by an electrical device connected between the charger and the battery which passes through voltage but not current.  Poor connections can also cause this.  Ensure the charger is properly connected to approved equipment. This error will automatically clear once the charger is reset by cycling DC or AC.
AlarmE014Configuration Error - Charger Cannot Support Number of Battery CellsThe charger will need to be reflashed to the correct settings.
AlarmE015Configuration Error - Algorithm Does Not Support Target Voltage ScalingThe charger will need to be reflashed to the correct settings.
AlarmE016Charger Programming Failure - GeneralRetry by removing and re-inserting the USB drive.  Ensure correct files are being used. Ensure the USB Flash Drive is properly formatted (FAT recommended) and retry.  Try a different USB drive. If error persists, contact Support.
AlarmE017USB Operation FailureThis could be caused by a faulty USB drive or connections.  If it persists, try a different USB drive.
AlarmE018Charger Programming Failure - CorruptionRetry by removing and re-inserting the USB drive.  Ensure correct files are being used. Ensure the USB Flash Drive is properly formatted (FAT recommended) and retry.  Try a different USB drive. If error persists, contact Support.
AlarmE019Charger Programming Failure - Incorrect SoftwareThe charger hardware does not support the software version being programmed. Existing software is left running.  Contact Support.
AlarmE020No Active Algorithm SelectedSelect a charge profile using the button or reflash the charger.
AlarmE021High Battery Voltage Error While ChargingBattery Voltage is too high as detected by the algorithm. Check the battery voltage and cable connections. This error will automatically clear once the condition has been corrected.
AlarmE022Low Battery Voltage Error While ChargingBattery Voltage is too low as detected by the algorithm.  Check the battery voltage and cable connections.  This error will automatically clear once the condition has been corrected.
AlarmE023AC Voltage HighAC voltage is too high. Connect charger to an AC source that provides stable AC between 85 - 270 VAC / 45-65 Hz. This error will automatically clear once the condition has been corrected.
AlarmE024Charger Initialization FailureThe charger has failed to turn on properly. Disconnect AC and battery for 30 seconds before retrying. If Error persists, contact Support.
AlarmE025AC Voltage Unstable and LowAC source is unstable. Could be caused by undersized generator and/or severely undersized/long AC cables. Connect charger to an AC source that is stable and between 85 - 270 VAC / 45-65 Hz. This error will automatically clear once the condition has been corrected.
AlarmE026USB Script FailureRetry by removing and re-inserting the USB drive.  Ensure correct files are being used. Ensure the USB Flash Drive is properly formatted (FAT recommended) and retry.  Try a different USB drive. If error persists, contact Support.
AlarmE027USB Over Current FaultUSB hardware overcurrent protection has been tripped. Remove and reinsert USB device. If the condition persists then try a different, brand-name USB device.
AlarmE028Incompatible AlgorithmThe selected charging profile is incompatible with the charger software. Update charger software or select a different charging profile.
AlarmE029CAN Bus Physical Layer ErrorCAN bus network error. Check the physical CAN connector, wiring, and other CAN modules for correct functioning.  Check termination is around 60 ohms.
AlarmE030Battery Reporting ErrorCharger has received an error from the battery module or it is in a pre-operational state.
AlarmE031Internal Charger Power Supply ErrorInternal supply rail error detected.  Remove AC and battery for minimum 30 seconds and retry charger. If the problem persists contact Support.
AlarmE032Missing CAN MessagesCAN heartbeats or PDOs were received and then timed out.  Check other CAN devices for function.
AlarmE033Configuration Error - Target Voltage Too HighThe charger configuration is asking for more voltage than the charger can deliver.  Charger reflash is required to correct this issue.
AlarmE034Configuration Error - Battery Capacity Not SupportedCharger is configured to with capacity scaling but algorithm selected does not support this feature.  Select a scalable algorithm or reflash the charger.
AlarmE035Configuration Error - Target Voltage Too LowThe charger configuration is asking for voltage below 20% of the charger nominal.  Charger reflash is required to correct this issue.
AlarmE036Battery Temperature Open CircuitCheck if sensor is connected correctly.  Install a temperature sensor.  Change to an algorithm that does not require a temperature sensor.
AlarmE037Charger Programming Failure - CANRe-try CANOpen download or re-program using the USB
AlarmE038Cooling Fan ErrorInspect fan to make sure the power wires are connected and the fan blades are not obstructed by debris.
AlarmE039Button Stuck DownInspect for objects on or near the button or damage to the button.  If alarm persists, replace charger.
AlarmE040Cooling Fan Voltage Too LowEnsure that the the fan is not stuck or drawing excess current, and that the correct fan part is installed.  
AlarmE041Software Error - GeneralSoftware internal configuration error, ensure configuration settings are correct and reflash charger
AlarmE042Configuration Error - CANSoftware internal configuration error, ensure configuration settings are correct and reflash charger
AlarmE043CANopen PDO CRC MismatchPower cycle all CAN nodes and charger.  Error will clear once sequence counter updates.  Reflash charger if this persists.  CAN only - not shown on display
AlarmE044CANopen PDO Sequence Count Not ChangingPower cycle all CAN nodes and charger.  Error will clear once sequence counter updates.  Reflash charger if this persists.  CAN only - not shown on display
AlarmE045Charger Output Open CircuitCharger did not see enough battery voltage.  Connect the battery in order to start charging.  This alarm is only displayed if configured.
AlarmE046CAN - Invalid PDO LengthPower cycle all CAN nodes and charger.  Error will clear once sequence counter updates.  Reflash charger if this persists.
AlarmE047ReservedFor internal use
AlarmE048Stackable Charging - Multiple MastersCheck the wiring harness to ensure only one charger has pins populated to be parallel charging master.
AlarmE049Stackable Charging - More Secondary Chargers Than Expected Make sure the right number of chargers are on the bus for this fixed configuration. Reset chargers to check if this alarm persists.
AlarmE051Stackable Charging - No MasterMaster device may be disconnected or powered down.
Check wiring harness. Check configuration of devices.  Reflash Master charger
AlarmE063Stackable Charging - Incompatible Secondary Charger(s)Query the master to identify which secondary has the bad configuration or interface version.
AlarmE050Stackable Charging - Single Charger Detected Stackable MessagesCheck the configuration of all chargers that are sharing this bus.
AlarmE052Stackable Charging - Fewer Secondary Chargers Than ExpectedSecondary chargers may be disconnected or powered down.
Check the wiring and power to the secondary chargers.
The alarm will automatically clear when the missing chargers come back online.
AlarmE054Stackable Charging - Secondary Charger Reverse PolarityCheck the DC connections of all chargers and the battery.
AlarmE055Stackable Charging - Secondary Charger DC Voltage MismatchEither they are disconnected from each other or there is an excessive series resistance which may result in cable overheating.  Check DC output wiring of the entire stack. The problem might be due to loose or corroded connections in the cabling.
AlarmE053Stackable Charging - Communications Lost With Secondary Charger(s)Check wiring harness and power to secondary chargers. Check to see if Secondary Chargers are issuing faults of their own.
AlarmE057ReservedCustomer specific implementation
AlarmE058ReservedCustomer specific implementation
AlarmE059J1939 Address ConflictInvestigate and disconnect non-compliant device from the bus.
Alternatively change the charger's configuration to exclude the conflicted address from its allowed range of addresses.
AlarmE060CAN Communications Never ReceivedCharger is waiting for this message to start.  Check CAN cabling. Ensure nodes configured to send expected messages
AlarmE061CAN Battery Current Report MismatchThe charger compares the Battery written current with its output current.  Check that the right current is being sent to the charger. Check if the output cable has a parallel branch.
AlarmE062CAN Battery Voltage Report MismatchThe charger compares the Battery written voltage with its output voltage.  Check that the correct voltage is being sent to the charger. Check that the output cable resistance matches the charger setting.  Check for other sources of voltage drop.
AlarmE056Stackable Charging - Secondary Charger Fault or AlarmCheck for alarms and faults reported by the secondary chargers.
AlarmE064J1939 Address - Charger Failed to ClaimThe most likely cause of this problem is that two or more chargers, configured for the same fixed address, have been connected to the same bus in error. Alternatively there could be a configuration issue and the addresses available to the charger are already being used by other customer devices on the bus.
AlarmE065J1939 Address - Other Device Failed to ClaimRead SPN 611 from the charger(s) that has raised this alarm. This will contain the 64-bit J1939 "Name" of the device that could not claim its address (see J1939-81 Network Management, Feb 2016, Section 4.2.1 ). 
If this device is another Delta-Q charger (manufacturer code 800, function Id 141) and this is a stackable charging system then possible causes include:
   i) Incorrectly configured chargers
   ii ) Address conflicts exist between the charger and other devices on the bus
   iii ) Master/Secondary wiring fault. 

The alarm will be cleared on charger reset - but may immediately trigger if the address conflict persists.
AlarmE066Battery Voltage Higher Than Configured MaximumCheck if the charger is connected to the right battery, or the maximum voltage configured is too low.
AlarmE067CAN Physical Layer Error - Before Messages ReceivedCANbus network error. Check the physical CAN connector, electrical bus conditions and other CAN modules for correct functioning.  For example check termination resistance is approximately 60ohms.
AlarmE068Missing CAN Messages While Not ChargingMonitored messages (Heartbeat, PGN, PDO) lost while charger output off. Check the networked CANbus device(s) for correct function and messages.
AlarmE069Accessory Power Output OvercurrentAccessory Power Output (APO) has too much load, please check circuits attached to Accessory Power Output (APO) for shorts or other circuit faults.
AlarmE084Incompatible ConfigurationVerify that selected configuration items are known to selected software version.
AlarmE087Charger Error Monitor TriggeredInternal error has been flagged due to not generating the regular "watchdog" message.  Check for low AC voltage or other abnormal conditions.  If this error re appears, replace the charger.
AlarmE088Charger Error Monitor Not StartedInternal error has been flagged due to loss of communications internally within the charger.  Check for abnormal conditions.  If this error re-appears, replace the charger.
AlarmE089Aux DC Output ErrorLost a condition to operate the Aux DC Output.  Check: Aux battery voltage between 9.7-14.5V, Traction battery voltage in range (see Design Guide).  Could also be internal hardware failure causing Aux DC Output to be off when commanded on by software or key switch.
AlarmE090EVSE Failed To Provide ACCharger is communication with EVSE but it is not providing AC. Check EVSE is connected to AC power.  Check cables and connections.  Check EVSE hardware or try another EVSE.
AlarmE091EVSE Failed To Turn Off ACCharger is communicating with EVSE but it is not turning off AC.  Check EVSE contactor for welding.  Check cables and connections.  If persists, try another EVSE.
AlarmE092Charger Reflash ErrorCheck the configuration file is appropriate for this charger model.  Check use of the correct version of programming tool or protocol.
AlarmE093Aux DC Output Short CircuitCheck for wiring errors. Check for faulty or shorted battery cells. Check for too much load on Aux Output.
AlarmE094AC Input Voltage High SpikesMonitor for stable AC voltage.  Frequent spikes above 280VAC may damage the charger input.
AlarmE095Safe Disconnect AlarmSafe disconnect pin not connected but the primary contact pin connected.  Ensure correct style of connector is used and the pins are installed correctly.
AlarmE096Charger Operating Voltage Too LowRaise charger output voltage above 21.0VDC to reduce thermal stress to internal components.

 

 