Product Series: QuiQ |
Article No: FAQ103 |
This lists the factory-loaded algorithm set for the various QuiQ Models in the Nilfisk Advance floor machine products. Make sure to verify your charger model number to determine the correct algorithm option.
912-2400-N1 / 912-3600-N1 / 912-3600-N2
Algorithm Slip A0010
3 T105 constant power dv/dt
7 J305 constant power dv/dt
11 Generic 200-255Ah flooded constant power dv/dt
12 Exide/Sonnenschein gel
21 Exide Flooded
26 Deka 8GGC2 Gel
43 Discover AGM
51 Exide/Sonnenschein 180Ah gel
72 Generic 250-335Ah Flooded constant power dv/dt
73 Generic 400Ah Flooded constant power dv/dt
912-2400-C1 / 912-3600-C1
Algorithm Slip A0004
1 Trojan Flooded
3 T105 constant power dv/dt
5 Trojan 30XHS
7 J305 constant power dv/dt
11 Generic 200-255Ah flooded constant power dv/dt
43 Discover AGM
52 Exide/Sonnenschein 105Ah gel
71 Generic 140-200Ah Flooded constant power dv/dt
72 Generic 250-335Ah Flooded constant power dv/dt
73 Generic 400Ah Flooded constant power dv/dt
912-2400-N1_02 / 912-3600-N1_03 / 913-2400-01 / 913-3600-W1
Algorithm Slip A0049
3 T105 constant power dv/dt
7 J305 constant power dv/dt
11 Generic 200-255Ah flooded constant power dv/dt
26 Deka 8GGC2 Gel
43 Discover AGM
72 Generic 250-335Ah Flooded constant power dv/dt
73 Generic 400Ah Flooded constant power dv/dt
125 Full River 200Ah AGM
141 Full River 300Ah AGM
151 Fullriver AGM 200-260Ah
912-3600-C2
Algorithm Slip A0053
1 Trojan Flooded
3 T105 constant power dv/dt
5 Trojan 30XHS
7 J305 constant power dv/dt
11 Generic 200-255Ah flooded constant power dv/dt
43 Discover AGM
52 Exide/Sonnenschein 105Ah gel
71 Generic 140-200Ah Flooded constant power dv/dt
72 Generic 250-335Ah Flooded constant power dv/dt
73 Generic 400Ah Flooded constant power dv/dt